-Round contact pin is adopted for modularized pin, unique GES structure, encircled interlacing technology, enhancing the performance of module transmission.
-50μgold plating process, better than partial gold-plating and flat golden structure to ensure the responsive stress.
-The grade of module monomer test is far above link-level module performance
-Non-welded-point design is adopted for the connection of contact pin and circuit board, lead-free and environmental-friendly, contact resistance is below 42mΩtransmission resistance, far beyond standard requirements with excellent consistency and stability.
2.1.2Information panel
Twoport flat information plate(PC8112)Built-up module of information port
-Connect to Keystone information module, ST, SC, LC, FC optical module
-The plate is in a double-layer structure, the screw is not necessary to be dismantled to clamp and maintain information module, screw hole is hidden from the surface to facilitate the construction and maintenance.
-The plate has single-ported, two-ported, three-ported and four-ported configuration to match multi-information ports; 1-4 ports are applied fast and conveniently to enhance the overall flexibility of the system.
-Modularized structure can be dismantled single-sided with protective doors.
- Retardant materials against high pressure is adopted for the plate, UL94V-0 grade
-The label box can mark various types of information points.
The plate is corrosion resisting and dull polished to prevent color fading and the scratch
-86 x 86 mm frame
2.1.3 Data jumper
GigaSUPEX Cat6 non-shielded jumper(PC46351X) GigaSUPEX Cat6 shielded jumper(PC46451X)
-Non-shielded and shielded jumper, aluminum foil shielded structure provides sound electromagnetic performance
-24AWG (non-shielded), 26AWG (shielded), multistrand flexible line, compatible with T568A/B.
-Sound electrical performance and continuous steadiness, ensure the transmission stability
-The length and color can be selected, antiskid plug sheath matching the color of the cable is installed
- Transmission performance exceeds TIA 568-C Cat6 and ISO/IEC 11801 Class E in an all-dimensional way
-Unique outer-sheath design, protect plug hasp to ensure the plug’s service life and reliability
-100% pass the exfactory inspection
2.2 Horizontal twisted-pair
2.2.1 Horizontal twisted-pair
GigaSUPEX Cat6 non-shielded twisted-pair(PC161211) GigaSUPEX Cat6 shielded twisted-pair(PC162211)
- Transmission performance exceeds TIA 568-C Cat6 and TIA 568-C Cat6 in an all-dimensional way, the bandwidth of standard products is 250MHz.
- A better shielding effectiveness from aluminum foil shield
- Excellent NEXT near-end crosstalk and RL performance, meet EMC required by the best environment
-Spiral cross skeleton may reduce damages caused by heavy load and kink during the installation to ensure installation quality.
-Pass the ETL, UL certification
-Several fireproofing outer sheath materials can be chosen by users: CM, CMR, CMP and LSZH
-25-years link quality assurance